{"id":9105,"date":"2015-09-09T08:36:10","date_gmt":"2015-09-09T08:36:10","guid":{"rendered":"https:\/\/ewnews.co.uk\/?p=9105"},"modified":"2015-09-09T08:36:10","modified_gmt":"2015-09-09T08:36:10","slug":"unmarked-chinese-cable-fails-copper-content-test","status":"publish","type":"post","link":"https:\/\/ewnews.co.uk\/index.php\/unmarked-chinese-cable-fails-copper-content-test\/","title":{"rendered":"Unmarked Chinese cable fails copper content test"},"content":{"rendered":"<p><a href=\"https:\/\/ewnews.co.uk\/wp-content\/uploads\/2015\/09\/LongZ-cable-failed-due-to-high-resistance.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-9107\" src=\"https:\/\/ewnews.co.uk\/wp-content\/uploads\/2015\/09\/LongZ-cable-failed-due-to-high-resistance-300x300.jpg\" alt=\"LongZ cable failed due to high resistance\" width=\"300\" height=\"300\" srcset=\"https:\/\/ewnews.co.uk\/wp-content\/uploads\/2015\/09\/LongZ-cable-failed-due-to-high-resistance-300x300.jpg 300w, https:\/\/ewnews.co.uk\/wp-content\/uploads\/2015\/09\/LongZ-cable-failed-due-to-high-resistance-150x150.jpg 150w, https:\/\/ewnews.co.uk\/wp-content\/uploads\/2015\/09\/LongZ-cable-failed-due-to-high-resistance-500x500.jpg 500w, https:\/\/ewnews.co.uk\/wp-content\/uploads\/2015\/09\/LongZ-cable-failed-due-to-high-resistance.jpg 510w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>The\u00a0Approved Cables Initiative (ACI) is reminding distributors of the importance of re-testing imported cable following the supply of a number of non-compliant Chinese cables to the UK.<\/p>\n<p>Earlier this year 85,000 metres of substandard rubber and TQ flexible cables from the Wasung Electric Cable Company in China, a subsidiary of the LongZ Group, were supplied to Doncaster Cables.<\/p>\n<p>As Doncaster Cables doesn\u2019t manufacture rubber cables, it sources these products from reputable and accredited manufacturers, usually within Europe, to complement its range of UK manufactured cables.<\/p>\n<p>On this occasion Doncaster Cables contacted the LongZ Group to quote for the supply of several sizes of rubber flexible cords. Requested samples were received and tested by Doncaster Cables\u2019 in-house test laboratory and were found to be in accordance with the required specifications.<\/p>\n<p>Placing an order with LongZ Group for nine different cables, Doncaster clearly stated that the required cables must fully comply with relevant British and European Standards, should carry the CE mark (in accordance with the Low Voltage Directive (LVD)) and be accompanied by certificates of conformity.<\/p>\n<p><strong>&#8216;High\u00a0resistance&#8217;<\/strong><\/p>\n<p>While the accompanying packing list and invoice for the ordered cable clearly stated the correct H05RR-F reference numbers and specific conductor sizes, when tested, in accordance with Doncaster Cables\u2019 usual procedures they all failed due to high resistance and in some cases sticking cores because of uncured rubber insulation.<\/p>\n<p>Details of Doncaster Cables\u2019 test reports were sent to LongZ Group where upon receipt the CEO expressed surprise at the findings and said that these cables were sold into the UK and throughout Europe on a regular basis without any problems.<\/p>\n<p>Once notified the ACI commissioned further independent testing on the cables\u2019 compliance with the required standards. Again all cables failed to meet the requirements of British and European Standards due to high conductor resistance. The cables also had issues re-strippability and carried incorrect cable markings with no manufacturer\u2019s identification or country of origin on the cable or labelling.<\/p>\n<p>The ACI has also now written to LongZ Group informing the CEO of its findings and asking for a response, but has yet to receive a reply.<\/p>\n<p>The ACI said: \u201cIn this instance, Doncaster Cables has followed a strict checking procedure which ensured that these cables haven\u2019t been made available for installation in UK buildings, although it appears that this may not be the first time these cable have been supplied to the UK.<\/p>\n<p>\u201cUnfortunately not all importers and distributors follow the same preventative measures hence the reason why we are also reminding contractors and installers of the importance of checking what has been specified against what you are actually installing. Had these cables been tested to BASEC criteria they would have been classed as Recall.\u201d<\/p>\n<p>The ACI is taking this case up with Trading Standards and BIS and will inform insurers, fire authorities, LABC and other UK and EU cable manufacturers of its findings.<\/p>\n<p>For further information about the ACI campaign visit <a href=\"http:\/\/www.aci.org.uk\" target=\"_blank\" rel=\"noopener\">www.aci.org.uk<\/a> or contact the ACI directly at <a href=\"mailto:info@aci.org.uk\">info@aci.org.uk<\/a> or on 0208 946 6978\/07973 636688.<\/p>\n<p><em>*Comparison of conductor resistance to BS requirement:<\/em><\/p>\n<p><em>H05RR-F 3 x 0.75 sq mm &#8211; +17.23%<\/em><\/p>\n<p><em>H05RR-F 3 x 1.00 sq mm &#8211; +11.80%<\/em><\/p>\n<p><em>H05RR-F 3 x 1.50 sq mm &#8211; +13.68%<\/em><\/p>\n<p><em>H05RR-F 3 x 2.50 sq mm &#8211; +11.02%<\/em><\/p>\n<p><em>H05RR-F 4 x 1.50 sq mm &#8211; +13.38%<\/em><\/p>\n<p><em>H05BN4-F 3 x 0.75 sq mm &#8211; +16.93%<\/em><\/p>\n<p><em>H05BN4-F 3 x 1.00 sq mm &#8211; +11.35%<\/em><\/p>\n<p><em>H05BN4-F 3 x 1.50 sq mm &#8211; +9.78%<\/em><\/p>\n<p><em>H05BN4-F 3 x 2.50 sq mm &#8211; +4.75%<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The\u00a0Approved Cables Initiative (ACI) is reminding distributors of the importance of re-testing imported cable following the supply of a number of non-compliant Chinese cables to the UK. Earlier this year 85,000 metres of substandard rubber and TQ flexible cables from the Wasung Electric Cable Company in China, a subsidiary of the LongZ Group, were supplied [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":9107,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[1002,1003,1004,1005],"class_list":["post-9105","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-approved-cables-initiative","tag-doncaster-cables","tag-longz-group","tag-low-voltage-directive","et-has-post-format-content","et_post_format-et-post-format-standard"],"jetpack_featured_media_url":"https:\/\/ewnews.co.uk\/wp-content\/uploads\/2015\/09\/LongZ-cable-failed-due-to-high-resistance.jpg","_links":{"self":[{"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/posts\/9105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/comments?post=9105"}],"version-history":[{"count":5,"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/posts\/9105\/revisions"}],"predecessor-version":[{"id":9111,"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/posts\/9105\/revisions\/9111"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/media\/9107"}],"wp:attachment":[{"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/media?parent=9105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/categories?post=9105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ewnews.co.uk\/index.php\/wp-json\/wp\/v2\/tags?post=9105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}